NYLON 6/6 33% GLASSFILLED | ||||
TICONA CELANESE® 33% GLASS-FIBER REINFORCED NYLON TYPE 6/6-1500-2 | ||||
Ticona Celanese® / Nylon Type 6/6-1500-2 | ||||
Glass-Reinforced
nylon has outstanding property improvements over un-reinforced
compositions. Improvements include greater tensile strength, deflection temperature, shear strength, improved Creep resistance, better dimensional stability, and lower moisture absorption and thermal expansion. The good wear resistance, electrical properties and low coefficient of friction of nylon 6/6 un-reinforced are retained. 33% glass-filled nylon is opaque tan in color. |
||||
APPLICATIONS | ||||
Fasteners
– Washers – Spacers – Insulators – Circuit Board Hardware –
Requiring greater stiffness and strength. |
||||
Approvals | Underwriters Laboratory UL File E39806 | |||
Federal Specification Type 1 Class 2 L-P-395B | ||||
Properties | ||||
Physical | Units | Test Method | DAM | 50% RH |
Specific Gravity | ASTM D792 | 1.38 | * | |
Density | lbs/in3 | ASTM D792 | 0.0498 | * |
Water Absorption (24 hours @ 73°F) | % | ASTM D570 | 1.0 | * |
Mechanical | Units | Test Method | DAM | 50% RH |
Tensile Strength | psi | ASTM D638 | 28,000 | 22,000 |
Elongation at Break | % | ASTM D638 | 2-4 | 3-5 |
Shear Strength | psi | ASTM D732 | 13,000 | 10,000 |
Compressive Strength | psi | ASTM D695 | 28,000 | 22,000 |
Flexural Strength | psi | ASTM D790 | 40,000 | 29,000 |
Flexural Modulus | psi | ASTM D790 | 1.2x106 | 0.9x106 |
Impact | Units | Test Method | DAM | 50% RH |
Izod Impact (Notched) | ft-lb/in | ASTM D256 | 2.2 | 2.6 |
Tensile Impact | ft-lb/in2 | ASTM D1822 | 70 | 80 |
Thermal | Units | Test Method | DAM | 50% RH |
Melting Point | °F | ASTM D789 | 495 | 495 |
Deflection Temperature (.46 Mpa) | ||||
66 psi | °F | ASTM D648 | 495 | * |
264 psi | °F | ASTM D648 | 485 | * |
Specific Heat (1.82 Mpa) | 0.3 | * | ||
Thermal Conductivity | BTU/m/ft2°F/in | 1.5 | * | |
Coefficient of Linear Thermal Expansion | in/in/°F | ASTM D696 | 1.6x105 | * |
Elevated Temperature Service | ||||
Long Range Service | °F | 150 | * | |
Long Range Service in Water | °F | 125 | * | |
Electrical | Units | Test Method | DAM | 50% RH |
Dielectric Strength | v/mil | ASTM D149 | 400 | * |
Dielectric Constant | ||||
@ 60 Hertz | ASTM D150 | 4.1 | * | |
@ 1000 Hertz | ASTM D150 | 4.0 | * | |
Volume Resistivity | ohm-om | ASTM D257 | 1014 | * |
Power Factor | ||||
@ 60 Hertz | ASTM D150 | 0.006 | * | |
@ 1000 Hertz | ASTM D150 | 0.009 | * | |
Hardness | Units | Test Method | DAM | 50% RH |
Hardness | Rockwell | ASTM D785 | M100 | M82 |
Miscellaneous | Units | Test Method | DAM | 50% RH |
Taber Abrasion (CS-17 wheel 1000 gram load) | mg/1000 cycles | ASTM D1044 | 20 | 16 |
Coefficient of Friction | ASTM D1894 | |||
Dynamic | ||||
vs. itself | 0.23 | * | ||
vs. steel | 0.15 | 0.17 | ||
vs. aluminum | 0.12 | 0.13 | ||
vs. brass | 0.11 | 1.24 | ||
Flammability | in/min | ASTM D635 | 1.1 | * |
UL94 | HB |
@ 1000 Hertz | ASTM D150 | 0.009 | * |