RTP 40% GLASS FIBER RIGID THERMOPLASTIC POLYURETHANE RTP 2307A (RTPU) | ||
RTP 2037A 40% GLASS FIBER RIGID THERMOPLASTIC POLYURETHANE (RTPU) | ||
RTP Engineering Plastics/ 40% Glass Fiber Rigid Thermoplastic Polyurethane RTP 2037A | ||
RTPU is an engineering thermoplastic material based on urethane chemistry. It is not an elastomer, but is amorphous, which signifies that the material will mold to a tight dimensional tolerance without warping. Its chemical resistance is similar to a semi-crystalline material. RTPU has high impact strength and is very light grey in color. | ||
APPLICATIONS | ||
Applications include agricultural and irrigation components, recreation and automotive equipment and electrical connectors. | ||
Properties | ||
Permanence | Nominal Values | Test Method |
Specific Gravity | 1.52 | ASTM D792 |
Mold Shrinkage, 1/8 in section | 0.001 in/in | ASTM D955 |
Mold Shrinkage, 1/4 in section | 0.002 in/in | ASTM D955 |
Water Absorption, 24 hours @ 73°F | 0.14% | ASTM D570 |
Mechanical | Nominal Values | Test Method |
Impact Strength, Izod, Notched 1/8 in section | 4 ft-lb/in | ASTM D256 |
Impact Strength, Izod, Unnotched 1/8 in section | 25 ft-lb/in | ASTM D256 |
Tensile Strength | 22,000 psi | ASTM D638 |
Tensile Elongation | 4.8% | ASTM D638 |
Tensile Modulus | 1.6 psi x 106 | ASTM D638 |
Flexural Strength | 34,000 psi | ASTM D790 |
Flexural Modulus | 1.4 psi x 106 | ASTM D790 |
Hardness, Rockwell R | 119 | ASTM D785 |
Electrical | Nominal Values | Test Method |
Dielectric Strength, S/T | 500 VPM | ASTM D149 |
Dielectric Constant, 1 MHz, Dry | 3.9 | ASTM D150 |
Dissipation Factor, 1 MHz, Dry | 0.012 | ASTM D150 |
Thermal | Nominal Values | Test Method |
Deflection Temperature @ 264 psi | 185°F | ASTM D648 |